“We have established a fast PCR-based micro flow-through p


“We have established a fast PCR-based micro flow-through process consisting of a helical constructed tube reactor. By this approach we can detect transcripts of measles and human papilloma virus (HPV) by continuous flow allowing for

reverse transcription (RT) and amplification Selleckchem SBC-115076 of cDNA. The micro reaction system consisted of two columnar reactors for thermostating the different reaction zones of the RT process and the amplification. The PCR reactor was built by asymmetric heating sections thus realizing different residence times and optimal conditions for denaturation, annealing and elongation. The system concept is based on low electrical power consumption (50-120 W) and is suited for portable diagnostic applications. The samples were applied in form of micro fluidic segments with single volumes between 65 and 130

nL injected into an inert carrier liquid inside a Teflon FEP tube with an inner diameter of 0.5 mm. Optimal amplification for template lengths of 292 bp (lambda-DNA), 127 bp (measles virus) and 95 bp (HPV) was achieved by maximal cycle times of 75 s.”
“The detection limits for cortical and brain stem sources associated with the auditory pathway are examined in order to analyse brain responses at the limits of the audible frequency range. The results obtained from this study are also relevant to other issues of auditory brain research. A complementary approach consisting of recordings of magnetoencephalographic (MEG) data and simulations of magnetic PLX3397 molecular weight field distributions is presented in this work. A biomagnetic CAL-101 inhibitor phantom consisting of a spherical volume filled with a saline solution and four current dipoles is built. The magnetic fields outside of the phantom generated by the current dipoles are then measured for a range of applied electric dipole moments with a planar multichannel SQUID magnetometer device and a helmet MEG gradiometer device. The inclusion of a magnetometer

system is expected to be more sensitive to brain stem sources compared with a gradiometer system. The same electrical and geometrical configuration is simulated in a forward calculation. From both the measured and the simulated data, the dipole positions are estimated using an inverse calculation. Results are obtained for the reconstruction accuracy as a function of applied electric dipole moment and depth of the current dipole. We found that both systems can localize cortical and subcortical sources at physiological dipole strength even for brain stem sources. Further, we found that a planar magnetometer system is more suitable if the position of the brain source can be restricted in a limited region of the brain. If this is not the case, a helmet-shaped sensor system offers more accurate source estimation.”
“Previous crystallographic and mutagenesis studies have implicated the role of a position-conserved hairpin loop in the metallo-beta-lactamases in substrate binding and catalysis.